• Users Online: 514
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2021  |  Volume : 33  |  Issue : 3  |  Page : 247-252

A comparative study between swedish interactive thresholding algorithm faster and swedish interactive thresholding algorithm standard in glaucoma patients


1 Department of Ophthalmology, Esperanza Hospital, Barcelona; Department of Ophthalmology, Creu Groga Ophthalmologic Institute, Calella, Spain
2 Department of Ophthalmology, Creu Groga Ophthalmologic Institute, Calella, Spain
3 Department of Ophthalmology, Esperanza Hospital, Barcelona, Spain

Correspondence Address:
Núria Mendieta
Hospital de l'Esperança, Passatge Sant Josep la Muntanya, 12, 08024 Barcelona
Spain
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joco.joco_148_20

Rights and Permissions

Purpose: To compare the results of the new strategy Swedish Interactive Thresholding Algorithm (SITA) Faster to the results of SITA Standard in patients with glaucoma. Methods: This was a cross-sectional study of 49 patients with glaucoma and previous experience with standard automated perimetry. Two consecutive tests were performed in random order, one with SITA Standard and another one with SITA Faster, in the studied eye of each patient. Comparisons were made for test time, mean deviation (MD), visual field index (VFI), and number of depressed points in pattern deviation map and total deviation map for every level of significance. Results: The average test time was 56% shorter with SITA Faster (P < 0.001). The intraclass correlation coefficient (ICC) for MD and VFI showed excellent agreement between both strategies, ICC = 0.98 (95% confidence interval [CI]: 0.96, 0.99) and ICC = 0.97 (95% CI: 0.95, 0.99), respectively. For the number of depressed points in total deviation map and pattern deviation map, ICC demonstrated good agreement with values between 0.8 and 0.95. Conclusions: Our study shows that SITA Faster is a shorter test with strong agreement with SITA Standard parameters. These results suggest that SITA Faster could replace SITA Standard for glaucoma diagnosis.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed521    
    Printed16    
    Emailed0    
    PDF Downloaded67    
    Comments [Add]    

Recommend this journal