• Users Online: 2125
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2022  |  Volume : 34  |  Issue : 4  |  Page : 436-441

Repeatability of choroidal thickness measurements in healthy subjects using RTVue XR optical coherence tomography


1 Department of Glaucoma, Anand Eye Institute, Hyderabad, Telangana, India
2 Department of Retina, Anand Eye Institute, Hyderabad, Telangana, India
3 Department of Optometry, Anand Eye Institute, Hyderabad, Telangana, India
4 Department of Statistics, Apollo Institute of Medical Sciences and Research, Hyderabad, Telangana, India

Correspondence Address:
Tarannum Mansoori
Department of Glaucoma, Anand Eye Institute, Habsiguda, 7.147/1, Nagendra Nagar, Hyderabad - 500 007, Telangana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joco.joco_168_22

Rights and Permissions

Purpose: To determine the intrasession, intraobserver, interobserver, and repeatability of choroidal thickness measurements in the healthy subjects imaged on enhanced depth imaging system of RTVue XR spectral domain optical coherence tomography (OCT). Methods: In this prospective, cross-sectional study, seventy eyes of 70 healthy volunteers with no known ocular disease were imaged using high-density scanning protocol of RTVue XR OCT. In a single imaging session, three sequential 12 mm macular-enhanced depth horizontal line scans were obtained through the fovea. Two experienced examiners measured the subfoveal choroidal thickness (SFCT), choroidal thickness at 500 μm nasally and temporally from the fovea in all the eyes, using the manual calipers provided in the software. The graders were masked to each other's measurement readings. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were used to measure the reliability within graders. Intergrader variability was assessed using Bland-Altman method and 95% limits of agreement (LoA). Results: Intragrader CR for grader one was 4.11 μm (95% confidence interval [CI], −2.84–11.06) for SFCT and 5.73 μm (95% CI, −3.71–15.16) for the grader two. Intragrader ICC of grader one ranged from 0.996 for SFCT to 0.994 for temporal choroidal thickness. Intragrader ICC of grader two ranged from 0.993 for temporal choroidal thickness to 0.991 for SFCT. Intergrader CR ranged from 5.24 μm (95% CI, −4.66–15.15) for SFCT to 5.89 μm (95% CI, −7.27–19.04) for temporal choroidal thickness. Intergrader 95% LoA for SFCT, nasal and temporal choroidal thickness were, −15.84–12.15 μm, −15.99–17.7 μm, and − 19.12–15.57 μm, respectively. Conclusion: Choroidal thickness measurements can be quantified with good repeatability using RTVue XR OCT, which would be useful in patients with chorioretinal diseases.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed124    
    Printed2    
    Emailed0    
    PDF Downloaded12    
    Comments [Add]    

Recommend this journal